In order to comply with the new 2008 PSP rule regarding gun firing modes, we recommend that Eclipse markers should be configured as follows -
Ego 7 / Ego 8
1. Enter the Setup menu;
2. Select (PRESET) (LOAD) and choose the PSP option;
3. Select (MAX ROF) and set the value to 13.0*;
4. Select (OFF ROF) and set the value to 13.0* or less (recommend 12.0);
5. Select (PRESET) (SAVE) and choose the USER 1 option to save these settings for future use.
6. Exit the Setup menu;
7. Check the rate of fire on a league approved ROF meter.
Ego 5 / Ego 6
1. Enter the Setup menu;
2. Select (MODE) and choose the RAMP 1 or PSP option;
3. Select (ROF CAP) and set the value to 13.0*;
4. Select (OFF ROF) and set the value to 13.0* or less (recommend 12.0);
5. Exit the Setup menu;
6. Check the rate of fire on a league approved ROF meter.
Etek / Etek 2
1. Enter the Setup menu;
2. Select Firing Mode (red) and set the value to 03.0 (Ramp 1);
3. Select Maximum ROF (green) and set the value to 13.0*;
4. Select Maximum ROF with BBSS Disabled (blue) and set the value to 13.0 or less (recommend 12.0);
5. Exit the Setup menu;
6. Check the rate of fire on a league approved ROF meter.
Planet Eclipse no longer provides software updates for the eBlade platform, however the following may prove useful in setting these products up to be compliant
E2 / Zero B
1. Fit fresh batteries to the loader that will be used and set the loader speed as required;
2. Enter the Setup menu;
3. Select (MODE) and choose the RAMP 1 or PSP option;
4. Set the COFF parameter to 40ms;
5. Enable the breech sensor;
6. Shoot the gun so that it ramps and measure the ROF on a rate of fire meter;
7. Adjust the COFF parameter and repeat 6 until the ROF is 13.0bps* (increasing COFF reduces ROF);
8. Check that CDELAY + CON + COFF is greater than 77ms and if not then increase CON;
9. Exit the Setup menu;
10. Check the rate of fire on a league approved ROF meter.
E1 (eBlade)
1. Fit fresh batteries to the loader that will be used and set the loader speed as required;
2. Enter the Setup menu;
3. Set the COFF parameter to 40ms;
4. Enable the breech sensor;
5. Shoot the gun as quickly as you can and measure the ROF on a rate of fire meter;
6. Adjust the COFF parameter and repeat 5 until the ROF is 13.0bps* (increasing COFF reduces ROF);
7. Check that CDELAY + CON + COFF is greater than 77ms and if not then increase CON;
8. Exit the Setup menu;
9. Check the rate of fire on a league approved ROF meter.